The five levels, the pace, the step height and what VO2max means. Here is what the published protocol says, and what it does not say.
The Chester Step Test is a submaximal test in five stages of two minutes. You step up and down on a step in time with an audio beat. The pace starts at 15 steps per minute and rises by 5 steps per minute every two minutes, so the last stage is 35 steps per minute. Your aerobic capacity (VO2max) is predicted from how your heart rate responds. It is not measured directly.
There is no pass mark that applies everywhere. The result required is set by whoever asks for the test, such as your employer or operator.
The original validation study describes the pace like this: the initial step rate was 15 steps per minute, and every 2 minutes the tempo increased by 5 steps per minute. The whole test is five stages and 10 minutes.
| Level (stage) | Time | Steps per minute |
|---|---|---|
| 1 | 0 to 2 min | 15 |
| 2 | 2 to 4 min | 20 |
| 3 | 4 to 6 min | 25 |
| 4 | 6 to 8 min | 30 |
| 5 | 8 to 10 min | 35 |
You follow the beat of the audio signal. You are not expected to complete all five levels: the test stops earlier when a stopping criterion is reached (see below).
The step height is not the same in every description of the test:
That is why a VO2max figure from one test should not be compared directly with a figure from a test on a different step height. If your employer or training provider specifies a step height, ask them. We do not state a recommended height here.
According to the 2004 study, the test was stopped when the person:
Heart rate is therefore followed throughout the test. The Danish Maritime Authority describes the Chester Step Test as a reproducible method that gives insight into your cardiovascular capacity, physical ability and endurance.
VO2max is the maximum oxygen uptake, a common measure of aerobic fitness, given in millilitres of oxygen per kilogram of body weight per minute (ml/kg/min). In a laboratory it is measured on a treadmill or bike. The Chester Step Test is a submaximal test, so it predicts VO2max from the heart rate response instead.
In the 2004 study, the prediction was compared with VO2max measured on a treadmill in the same people. The correlation was 0.92, and the standard error of the estimate was 3.9 ml/kg/min. In plain words: the estimate follows the measured value closely across a group, but an individual estimate can still differ by several units, so it is not the same as a laboratory measurement.
The APTA summary also notes that people on medication such as beta-blockers may respond inaccurately to the test, which is worth mentioning to whoever tests you.
The sources we use do not set a universal pass level. The Global Wind Organisation (GWO) makes no requirements for a medical assessment and says it is the employer who decides which examinations you need. That also goes for the result required, so ask your employer, operator or training provider which level or VO2max figure they require.
For seafarers on Danish ships, the Danish Maritime Authority's rules mention the Chester Step Test as a possible test when a seafarer has a BMI above 40. It cannot on its own be the basis for being found unfit and must be part of an overall assessment.
Read more in our guide Chester Step Test: how to prepare, and see GWO training and medicals for what GWO itself requires.
Prices include VAT and are the same as on the price list.
Book the Chester Step Test
Chester Step Test on its own DKK 750. The package GWO Wind OEUK with Chester Step Test DKK 2,330. Prices incl. VAT.
Need an appointment today? Call +45 70 60 33 38.
Sources: Sykes and Roberts, The Chester step test, Physiotherapy 2004 (abstract and methods); Peroy-Badal et al., Healthcare 2022 (A 20 cm step and the five stages); APTA, Chester Step Test (CST) (step heights, medication); Global Wind Organisation, Do I need a medical examination to participate in GWO training?; Danish order on medical examination of seafarers and fishermen, BEK no. 1463 of 05/12/2023, section 32 and annex 4. Read October 2026. This page describes the published protocol. It does not state a pass level or the step height used at any specific clinic, and it does not replace the doctor's assessment on the day.
Five levels of two minutes each, 10 minutes in total. The pace is 15, 20, 25, 30 and 35 steps per minute. The test stops earlier if you reach the stopping criteria.
It varies. The 2004 validation study used a 30 cm step and a 2022 study used a 20 cm step. APTA writes that 15 cm and 20 cm steps may be used and that changing the height deviates from the original protocol.
No, it predicts it. It is a submaximal test, and VO2max is estimated from your heart rate response. In the 2004 study the standard error of the estimate was 3.9 ml/kg/min compared with a treadmill test.
There is no pass level that applies everywhere. The result required is set by whoever asks for the test, for example the employer or operator. GWO makes no requirements for a medical assessment.
In the 2004 study, the test stopped when the person reached 80% of their maximum predicted heart rate, reported a rating of perceived exertion of 15 on the Borg scale, or reached the end of the 10-minute test.
The five stages take 10 minutes if you complete them all.
Seafarer and petroleum doctor with more than 20,000 medical examinations. OEUK-approved since 2006 and approved in Denmark, Norway, the UK and Sweden.